Open/Close actuators

Actuators for Type JZ and JZ-Low leakage multileaf dampers

  • Change of the damper blade position for two different operating situations
  • Supply voltage 24 V AC/DC or 230 V AC
  • Control input signal: 1-wire control or 2-wire control (3-point)
  • Mechanical stops
  • Retrofit possible


Optional equipment and accessories

  • Fast-running actuators and spring return actuators
  • Auxiliary switch

leer más

layer

Quadrant stays and limit switches

Quadrant stay for the stepless adjustment and locking of multileaf dampers without an actuator. Limit switches for OPEN and/or CLOSED positions may be fitted additionally

  • Micro switch with connecting cable
  • Quadrant stay with position indicator
  • Steel and stainless steel constructions
  • Limit switches for capturing the end positions of multileaf dampers

leer más

layer

Modulating actuators

Modulating actuators for Type JZ and JZ-Low leakage multileaf dampers

  • Various damper blade positions
  • Supply voltage 24 V AC/DC
  • Control input signal: Signal voltage 2 – 10 V for modulating actuators
  • Mechanical stops
  • Retrofit possible

leer más

layer

Explosion-proof actuators

Explosion-proof actuators for Type JZ and JZ-Low leakage multileaf dampers

  • ATEX-compliant construction and parts
  • Approved for gases, mists and vapours in zones 1 and 2, and for dusts in zones 21 and 22
  • Supply voltage 24 V AC/DC or 230 V AC
  • Pneumatic actuators with torque 8 – 70 Nm
  • Electric actuator with torque 15 or 30 Nm
  • Pneumatic: Double acting or single acting actuator for a positive lock connection with a multileaf damper
  • Electric: Spring return actuator for a positive lock connection with a multileaf damper


Optional equipment and accessories

  • Solenoid valve 24 V or 230 V
  • Limit switches

leer más

layer

Pneumatic actuators

Pneumatic actuators for Type JZ and JZ-Low leakage multileaf dampers

  • Change of the damper blade position for two different operating situations
  • Control input signal: Operating pressure of 1.2 – 6 bar
  • Pneumatic actuator, single acting or double acting
  • Torque 8 – 70 Nm
  • Retrofit possible


Optional equipment and accessories

  • Solenoid valve 24 V or 230 V
  • Limit switches

leer más

Compartir

Recomendar

Recomendar el contenido de esta página, mandar por mail.

Los campos marcados con un (*) sin imprescindibles de cumplimentar

Compartir

Gracias por su recomendación!

Su recomendación ha sido enviada y llegará a su destino en breve.


Contacto

Estamos aquí para atenderles

Visual contact Visual contact

Por favor mande su solicitud
Tel.: +34 976 50 02 50 | Fax: +34 976 50 09 04

Los campos marcados con un (*) sin imprescindibles de cumplimentar

Contacto

Gracias por su mensaje.

Visual contact Visual contact

Su mensaje ha sido enviado correctamente, en breve será atendido.
En seguida nos pondremos en contacto con Vd.
Para información general sobre productos o servicios, por favor llamar al:
Tel.: +34 976 50 02 50 | Fax: +34 976 50 09 04

Contacto

Estamos aquí para atenderles

Visual contact Visual contact

Por favor mande su solicitud
Tel.: +34 976 50 02 50 | Fax: +34 976 50 09 04

Archivo adjunto (Max. 10MB)

Los campos marcados con un (*) sin imprescindibles de cumplimentar

Contacto

Gracias por su mensaje.

Visual contact Visual contact

Su mensaje ha sido enviado correctamente, en breve será atendido.
En seguida nos pondremos en contacto con Vd.
Para información general sobre productos o servicios, por favor llamar al:
Tel.: +34 976 50 02 50 | Fax: +34 976 50 09 04