X-AIRCONTROL

Modular, stand-alone room control system, specially for decentralised ventilation systems (with bus communication as an option)

 

Easy-to-operate single room control system which can be combined with façade ventilation units to provide demand-based ventilation and extract ventilation and enable the control of the water-side components of the heating and cooling circuits

  • Plug and play solution
  • Main PCB for connecting the integral components
  • Master PCB for connecting components which are required for each room, e.g. control panels or sensors
  • Control valves with G½" external thread and flat seal
  • 24 V AC or 230 V AC supply voltage
  • Thermoelectric valve actuator, 0 – 10 V, 24 V DC


Optional equipment and accessories

  • Various sensors, e.g. PIR sensor, temperature sensor, room air quality sensor or humidity sensor
  • Plug-in real time clock module (RTC) for time-dependent operating modes
  • Expansion modules with interfaces for open bus protocols (LON, BACnet and Modbus)
  • Control panel
small_tab1_X-AIRCONTROL
  • Application
  • Description

Application

  • Single room control system to be combined with decentralised ventilation units
  • Control of the functions of a decentralised ventilation unit
  • Individual control strategies
  • Modular control equipment with expansion PCBs that allow for the individual adjustment of functions to the project-specific conditions
  • Optional expansion to allow for communication with the BMS using the LON, BACnet or Modbus protocol
  • Plug-in communication cable for easy wiring (plug and play)

Special characteristics

  • Modular control system with several components that can be individually combined
  • LON, BACnet or Modbus interface as an option
  • Master-slave combinations are available (up to 15 slaves per master)
  • Valves with G½" external thread and flat seal
  • Valves can be used for up to PN 16
  • Valve actuator with bayonet fixing

Components

  • Control module (main PCB)
  • Room module (master)
  • Expansion module RTC (real time clock)
  • Expansion module LON
  • Expansion module BACnet/Modbus
  • VVP47.10-x.xx - straight-way valve (KVS 0.25; 0.4; 0.63 or 1.0)
  • Compression coupler
  • Valve actuator 24 V DC, control signal 0 – 10 V, modulating
  • Temperature sensors for fresh air, supply air etc. (e.g. NTC 10 kΩ)
  • Humidity sensor
  • VOC sensor
  • Control panel
  • Alternative control panel with digital display
  • Alternative control panel for automatic control (e.g. in schools)

Accessories

  • 5 m configuration cable and USB-RS485 adapter
  • Wireless communication with BlueCon adapter

Materials and surfaces

  • Casing made of galvanised steel, powder-coated RAL 9005 (unless fitted inside the decentralised ventilation unit)

Información técnica

  • Function
  • Specification text
  • Order code

Functional description

The control module, which is required for each decentralised ventilation unit, controls all functions that are necessary for operation, e.g. providing the control signal for fans and actuators.

When a room module is added, the control module can be used as a master module.

Additional inputs and interfaces allow for the connection of components that are required for room control.

Adding the RTC module to the room module allows for using a timer programme; adding a LON or BACnet/Modbus PCB to the room module allows for integrating the room module with a BMS.

Special characteristics

  • Modular control system with several components that can be individually combined
  • LON, BACnet or Modbus interface as an option
  • Master-slave combinations are available (up to 15 slaves per master)
  • Valves with G½" external thread and flat seal
  • Valves can be used for up to PN 16
  • Valve actuator with bayonet fixing

Materials and surfaces

  • Casing made of galvanised steel, powder-coated RAL 9005 (unless fitted inside the decentralised ventilation unit)

Technical data

  • Operating temperature: 0 to 50 °C
  • Relative humidity: < 90 %, non-condensing
  • Air pressure: > 700 hPa
  • Storage temperature: –20 to 70 °C
  • Power consumption: 6.5 to 14.5 W, depending on equipment
x-airconrol

Compartir

Recomendar

Recomendar el contenido de esta página, mandar por mail.

Los campos marcados con un (*) sin imprescindibles de cumplimentar

Compartir

Gracias por su recomendación!

Su recomendación ha sido enviada y llegará a su destino en breve.


Contacto

Estamos aquí para atenderles

Visual contact Visual contact

Por favor mande su solicitud
Tel.: +34 976 50 02 50 | Fax: +34 976 50 09 04

Los campos marcados con un (*) sin imprescindibles de cumplimentar

Contacto

Gracias por su mensaje.

Visual contact Visual contact

Su mensaje ha sido enviado correctamente, en breve será atendido.
En seguida nos pondremos en contacto con Vd.
Para información general sobre productos o servicios, por favor llamar al:
Tel.: +34 976 50 02 50 | Fax: +34 976 50 09 04

Contacto

Estamos aquí para atenderles

Visual contact Visual contact

Por favor mande su solicitud
Tel.: +34 976 50 02 50 | Fax: +34 976 50 09 04

Archivo adjunto (Max. 10MB)

Los campos marcados con un (*) sin imprescindibles de cumplimentar

Contacto

Gracias por su mensaje.

Visual contact Visual contact

Su mensaje ha sido enviado correctamente, en breve será atendido.
En seguida nos pondremos en contacto con Vd.
Para información general sobre productos o servicios, por favor llamar al:
Tel.: +34 976 50 02 50 | Fax: +34 976 50 09 04