Enclosure X-AIR-PCASE230V (closed lid)
Installation housing Delivery status

Installation housing Delivery status

Installation housing with on-site addition Zone module

Installation housing with on-site addition Zone module
Installation housing with on-site addition Zone module and splitter
Installation housing Delivery status

X-AIR-PCASE230V

X-AIR-PCASE230V enclosure for one zone module or one zone master.


X-AIRCONTROL enclosure for the fitting (by others) of a zone module or a zone master in a zone (room)

  • 24 V AC power supply to the zone module or zone master through an integral transformer
  • Connection of 230 V AC and looping through with 4-wire double terminals
  • Optional fitting of an X-SENS-SPLITTER four-way splitter
  • Pre-wired

General information


Application

  • Type X-AIR-PCASE230V enclosure for the fitting of a zone module or zone master

  • Voltage supply to a zone module or a zone master and any connected components, such as volume flow controllers, valve actuators or sensors

  • For the fitting of an X-SENS-SPLITTER four-way splitter

  • Wall installation

  • Ceiling installation (optional)


Special features

  • Simple wall installation thanks to removable mounting bracket

  • Simple installation of a zone module or zone master and the four-way splitter X-SENS-SPLITTER thanks to integral DIN mounting rails

  • Transformer 230 V/24 V AC, including micro fuse, installed and wired

  • Supply voltage connection and looping through with 4-wire double terminals

  • The enclosure is delivered without a zone module or zone master



Parts and characteristics

  • For supply voltage 230 V AC, 50 Hz

  • 4-wire double terminals for looping through (L1/N/PE)

  • Transformer with micro fuse 230 V AC to 24 V AC

  • Integral mounting rail

  • 2-pole connection plug to connect a zone module or zone master to the supply voltage

  • Integral strain relief

  • Bracket for wall installation



Useful additions

  • Zone modules X-AIR-ZMO-MP, X-AIR-ZMO-MOD or X-AIR-ZMO-ANA

  • X-AIR-ZMAS zone master module

  • Four-way splitter X-SENS-SPLITTER

  • X-AIR-PCASE-C optional mounting bracket for ceiling installation of X-AIR-PCASE230V




Materials and surfaces

  • Casing in ABS plastic, UL 94 V-0

  • Grey, RAL 7037



Maintenance

  • Maintenance-free as construction and materials are not subject to wear

  • Inspection and cleaning; regular cleaning from dust is recommended



Información técnica

Function, Technical data, Specification text, Order code

  • Function
  • TECHNICAL DATA
  • SPECIFICATION TEXT
  • ORDER CODE

The X-AIR-PCASE230V enclosure is used for the fitting of a zone module or zone master. The X-AIR-PCASE230V enclosure comes with two integral mounting rails for a zone module / zone master, a four-way splitter X-SENS-SPLITTER and other components. The enclosure is made of ABS plastic. A pre-wired transformer in the X-AIR-PCASE230V supplies the zone module or the zone master via a two-pole connection plug with 24 V AC. The transformer has a micro fuse. As standard, the X-AIR-PCASE230V comes with a mounting bracket with four fixing holes (Ø5 mm) for wall installation. If you need to fix X-AIR-PCASE230V to a ceiling, use the X-AIR.PCASE-C mounting bracket (accessory). The X-AIR-PCASE230V is delivered without a zone module, zone master or X-SENS-SPLITTER. These have to be installed on site, by others. 3 x 4-wire feed-through terminal blocks L1/N/PE are provided for the connection of the supply voltage. Cables can be fed through the rubber membranes at the side. The lid of the X-AIR-PCASE230V is secured with a safety device that prevents it from being opened by unauthorised persons. It can only be opened with a Phillips screwdriver.



Supply voltage230 V AC ±10%, 50 Hz
Power consumption (transformer)35 VA max.
Micro fuse (transformer)T250 mA (Ø5 × 20 mm, EN 60127-2/III)
Connection (spring-loaded terminals, 2.5 mm² max.)4-wire double terminals
Temperature – operation-10 to 40 °C
Temperature – storage-20 to 50 °C
Protection levelIP 20 (EN 60529)
IEC protection classI (protective earth)
Installation locationWall or ceiling installation (optional)
Dimensions with wall mounting bracket (B × T × H)Approx. 282 × 267 × 155 mm with closed lid, approx. 282 × 300 × 380 mm with open lid
Dimensions with ceiling mounting bracket (B × T × H)Approx. 282 × 330 × 150 mm with closed lid, approx. 282 × 330 × 380 mm with open lid
EnclosureABS plastic, UL 94 V-0, grey (RAL 7037)
WeightApprox. 2700 g


The X-AIR-PCASE230V enclosure is used for the fitting of a zone module or zone master. The enclosure is a plastic casing made of ABS. As standard, PCASE230V comes with a mounting bracket for wall installation. The mounting bracket has 4 holes (Ø5 mm) so that you can screw-fix it to the wall. If you need to fix the enclosure to a ceiling, use the X-AIR.PCASE-C mounting bracket (accessory). The X-AIR-PCASE230V is intended for use with a zone master or zone module and fitted with two mounting rails for installation. The X-AIR-PCASE230V is delivered without a zone module, zone master or splitter. These have to be installed on site, by others. 3 x 4-wire feed-through terminal blocks L1/N/PE are provided for the connection of the supply voltage. A 230 V/24 V AC transformer including micro fuse for supplying voltage to the various components is factory installed and wired. Cables can be fed through the rubber membranes at the side. The lid of the X-AIR-PCASE230V is secured with a safety device that prevents it from being opened by unauthorised persons. It can only be opened with a Phillips screwdriver.


Special features


  • Simple wall installation thanks to removable mounting bracket

  • Simple installation of a zone module or zone master and the four-way splitter X-SENS-SPLITTER thanks to integral DIN mounting rails

  • Transformer 230 V/24 V AC, including micro fuse, installed and wired

  • Supply voltage connection and looping through with 4-wire double terminals

  • The enclosure is delivered without a zone module or zone master



Materials and surfaces


  • Casing in ABS plastic, UL 94 V-0

  • Grey, RAL 7037


Technical data


  • Supply voltage: 230 V AC ±10%, 50 Hz

  • Power consumption (transformer): 35 VA max.

  • Micro fuse (transformer): T250 mA (Ø5 × 20 mm, EN 60127-2/III)

  • Connection (spring-loaded terminals, max. 2.5 mm²: ​4-wire double terminals

  • Temperature – operation: -10 – 40°C

  • Temperature – storage: -20 – 50°C

  • Degree of protection: IP20 (EN 60529)

  • IEC protection class: I (protective conductor)

  • Dimensions with wall mounting bracket (B × T × H): approx. 282 × 267 × 155 mm with closed lid, approx. 282 × 300 × 380 mm with open lid

  • Dimensions with ceiling mounting bracket (B × T × H): approx. 282 × 330 × 150 mm with closed lid, approx. 282 × 330 × 380 mm with open lid

  • Casing: ABS plastic, UL 94 V-0, grey (RAL 7037)

  • Weight: Approx. 2700 g



X-AIR-PCASE230V
|
1

1 TypeX-AIR-PCASE230V Useful additionsX-AIR ZMO-ZMAS Zone master
X-AIR ZMO MOD Modbus RTU zone module
X-AIR-ZMO-ANA Analogue zone module
X-SENS-SPLITTER Four-way splitter
X-AIR-PCASE-C Ceiling mounting bracket       

Dimensions, Product details

  • DIMENSIONS
  • PRODUKTDETAILS

Schematic representation of X-AIRCONTROL Schematic representation of X-AIRCONTROL
1 cable entry
2 wall brackets (scope of delivery)
3 Installation space for zone module or master
4 connector for zone module or master (24 VAC)
Connection for:
5 Supply voltage 230 VAC
6 transformer 230V / 24V AC
7 Installation location for four-way distributor X-SENS-SPLITTER

Installation and commissioning

  • Screw-fix the supplied brackets to the wall or ceiling as required, then press the X-AIR-PCASE230V onto the brackets until it locks into place.
  • Mount the zone module or zone master and, if required, the four-way splitter X-SENS-SPLITTER onto the mounting rails.
  • Wire up the zone master or zone module and, if necessary, the four-way splitter
  • Use the two-pole plug connector to connect the zone module or zone master to the 24 V AC supply voltage (for zone modules: pay attention to choose the correct position)
  • Connect the 230 V AC supply voltage
  • Close the lid with the safety device
  • Check the function of all the connected components

Descargas

Información sobre el producto

Certificados

Manuales de funcionamiento

production {"X-Frame-Options"=>"SAMEORIGIN", "X-XSS-Protection"=>"1; mode=block", "X-Content-Type-Options"=>"nosniff", "X-Download-Options"=>"noopen", "X-Permitted-Cross-Domain-Policies"=>"none", "Referrer-Policy"=>"strict-origin-when-cross-origin", "Content-Security-Policy"=>"frame-ancestors 'self' https://api.scrivito.com https://punchoutcommerce.com https://www.trox.de https://trox-extern.com https://psp40.onventis.com https://psp22.onventis.com https://trox4u.troxgroup.com", "Strict-Transport-Security"=>"max-age=31536000; includeSubDomains", "Content-Type"=>"text/html; charset=utf-8"}

Compartir la página

Recomendar la página

La página puede ser recomendada compartiendo este enlace.

Los campos marcados con un asterísco (*) son de obligado cumplimiento.

Contacto

¡Gracias por su mensaje!

Su recomendación ha sido remitida con éxito.

Contacto

Estamos aquí para ayudarle

Por favor indique el asunto de su consulta y sus datos de contacto.
Tel.: +34 976 50 02 50 | Fax: +34 976 50 09 04

Los campos marcados con un asterísco (*) son de obligado cumplimiento.

Contacto

¡Gracias por su mensaje!

Su mensaje se ha recibido con éxito en el buzón del SAT de TROX.
En seguida nos pondremos en contacto con usted.
En caso de que disponga de cuestiones adicionales, puede contactar con nosotros en: Tel.: +34 976 50 02 50 | Fax: +34 976 50 09 04

Contacto

Estamos aquí para ayudarle

Por favor indique el asunto de su consulta y sus datos de contacto.
Tel.: +34 976 50 02 50 | Fax: +34 976 50 09 04

Adjunto (máx. 10MB)

Los campos marcados con un asterísco (*) son de obligado cumplimiento.

Contacto

¡Gracias por su mensaje!

Su mensaje se ha recibido con éxito en el buzón del SAT de TROX.
En seguida nos pondremos en contacto con usted.
En caso de que disponga de cuestiones adicionales, puede contactar con nosotros en: Tel.: +34 976 50 02 50 | Fax: +34 976 50 09 04