Type MFI

Compact construction for large volume flow rates

 

Prefilters or final filters for the separation of fine dust, or particulate filters for the most critical requirements in ventilation systems

  • Filter classes M5, M6, F7, F9, E10, E11, H13, H14
  • Performance data to EN 779 or EN 1822
  • Eurovent certification for fine dust filters
  • Meets the hygiene requirements of VDI 6022
  • Highest energy efficiency according to Eurovent document 4/11
  • Filter media for special requirements, glass fibre papers, with spacers made of hot-melt adhesive or textile threads
  • Low initial differential pressure due to ideal pleat position and largest possible filter area
  • Compact depth construction
  • Fitting into standard cell frames for filter walls (type SIF), into mounting frames (type MF), or into universal casings (type UCA) for duct installation
v2.5.1.2
Actualizando el código de pedido
Guardar la configuración
Calculando precio
Clasificación del filtro
ePM1
ePM10
E10
E11
H13
H14
Ejecución
PLA
GAL
SPC
Anchura
592
Altura
287
402
490
592
Profundidad
292
Número de paneles filtrantes
6
8
Rejilla de protección
PD
Junta
FNU
FND
Ensayo
OT
OTC
Actualizando los datos técnicos
Texto para especificación: MFI-H13-GAL/592x592x292x8/PD/FND/OT
Actualizando el texto para especificación

Mini Pleat filter insert type MFI for the separation of fine dust and suspended particles such as aerosols, toxic dusts, viruses and bacteria from the supply and extract air in ventilation systems. .
Use as fine dust filters, i.e. as prefilters or final filters in ventilation systems; or as particulate filters, i.e. main or final filters for the most critical requirements of air cleanliness and sterility in areas such as industry, research, medicine, pharmaceuticals, and nuclear engineering.
Compact depth construction, suitable for systems with high volume flow rates and a requirement for long filter life.
The filter medium is made of high-quality, moisture-resistant glass fibre papers, with spacers.
Low initial differential pressure due to ideal pleat position and largest possible filter area.
Mini Pleat filter inserts available in market sizes, filter groups ISO ePM10, ISO ePM1 (fine dust filters) and EPA, HEPA (particulate filters).
As a fine dust filter (filter groups according to ISO 16890) as standard without seal, optionally available with flat seal, as a particulate filter Mini Pleat filter inserts are equipped with a flat seal.
Filter classes E11, H13 and H14 as standard with grip protection on the downstream side.
Mini Pleat filter insert as fine dust filters are certified according to Eurovent.
Mini Pleat filter inserts MFI are hygienic conform to VDI 6022.

VARIANTE
H13 Clasificación del filtro: Filtro absoluto en cumplimiento con EN 1822
GAL Ejecución: Marco de acero galvanizado
592 Anchura: 592
592 Altura : 592
292 Profundidad: 292
8 Número de paneles filtrantes: 8
PD Rejilla de protección: Rejilla de protección detrás de la unidad
FND Junta: Sección plana con junta después de la unidad
OT Ensayo: Ensayo de niebla de aceite

DATOS DEL PRODUCTO
Caudal de aire qv 3.000 m³/h
Pérdida de carga inicial Δpi 265 Pa
Anchura de filtro Bf 592 mm
Altura del filtro Hf 592 mm
Profundidad del filtro Tf 292 mm
Superficie media filtrante Afm 30,6 m²
Caudal nominal de aire qv,nom 3.000 m³/h
Pérdida de carga inicial nominal Δpi,nom 265 Pa

Manufacturer: TROX GmbH
Type: MFI-H13-GAL/592x592x292x8/PD/FND/OT

Mostrar texto completo Ocultar texto completo

Application

Application

  • Mini Pleat filter insert type MFI for the separation of fine dust and suspended particles such as aerosols, toxic dusts, viruses and bacteria from the supply and extract air in ventilation systems with large volume flow rates and the requirement for long filter life
  • Fine dust filter: Prefilter or final filter for the separation of fine dust in ventilation systems.
  • Particulate filter: Main or final filter used for the most critical requirements of air cleanliness and sterility in areas such as industry, research, medicine, pharmaceuticals, and nuclear engineering

Special characteristics

  • Leakage test is standard for all particulate filters of classes H13, H14

Description

Filter classes

  • Fine dust filters M5, M6, F7, F9
  • Particulate filters E10, E11, H13, H14

Construction

  • PLA: Frame made of plastic
  • SPC Frame made of galvanised steel, powder-coated RAL 9010, pure white

Options

  • Number of filter packs
  • FNU: Flat section seal on the upstream side
  • FND: Flat section seal on the downstream side
  • OT: Oil mist test (only for filter classes H13, H14)
  • OTC: Oil mist test with certificate (only for filter classes H13, H14)

Useful additions

  • Filter wall (SIF)
  • Mounting frame (MF)
  • Universal casing (UCA)

Construction features

  • As standard, constructions PLA and SPC used as fine dust filters have no seal.
  • Constructions PLA and SPC with optional flat section seal
  • Construction SPC as particulate filter with flat section seal. Filter classes E11, H13 and H14 with protection grid on the downstream side

Materials and surfaces

  • Filter media made of high-quality, moisture-resistant glass fibre papers, pleated
  • Spacers provide a uniform spacing of the pleats
  • Joint sealing compound made of permanently elastic two-component polyurethane adhesive
  • Frame made of plastic (option) or of galvanised sheet steel, powder-coated RAL 9010, pure white

Información técnica

  • Function
  • Specification text
  • Order code
mfi

 

Mini Pleat filter insert type MFI for the separation of fine dust and suspended particles such as aerosols, toxic dusts, viruses and bacteria from the supply and extract air in ventilation systems.

Use as fine dust filters, i.e. as prefilters or final filters in ventilation systems; or as particulate filters, i.e. main or final filters for the most critical requirements of air cleanliness and sterility in areas such as industry, research, medicine, pharmaceuticals, and nuclear engineering.

Compact depth construction, suitable for systems with high volume flow rates and a requirement for long filter life.

Filter medium is made of high-quality, moisture-resistant glass fibre papers, with spacers.

Low initial differential pressure due to ideal pleat position and largest possible filter area.

Mini Pleat filter inserts are available in all commercial sizes, filter classes M5, M6, F7, F9, E10, E11, H13, H14.

As standard, fine dust filters have no seal; flat section seal as an option.

As particulate filters with flat section seal. Filter classes E11, H13 and H14 with protection grid at the side.

Mini Pleat filter inserts used as fine dust filters are certified by Eurovent and meet the hygiene requirements of VDI 6022.

Special characteristics

  • Leakage test is standard for all particulate filters of classes H13, H14

Materials and surfaces

  • Filter media made of high-quality, moisture-resistant glass fibre papers, pleated
  • Spacers provide a uniform spacing of the pleats
  • Joint sealing compound made of permanently elastic two-component polyurethane adhesive
  • Frame made of plastic (option) or of galvanised sheet steel, powder-coated RAL 9010, pure white

Construction

  • PLA: Frame made of plastic
  • SPC Frame made of galvanised steel, powder-coated RAL 9010, pure white

Sizing data

  • Filter class
  • Volume flow rate [m³/h]
  • Initial differential pressure [Pa]
  • Nominal size [mm]
mfi

Descargas

Información sobre el producto

Compartir la página

Recomendar la página

La página puede ser recomendada compartiendo este enlace.

Los campos marcados con un asterísco (*) son de obligado cumplimiento.

Contacto

¡Gracias por su mensaje!

Su recomendación ha sido remitida con éxito.

Contacto

Estamos aquí para ayudarle

Visual contact Visual contact

Por favor indique el asunto de su consulta y sus datos de contacto.
Tel.: +34 976 50 02 50 | Fax: +34 976 50 09 04

Los campos marcados con un asterísco (*) son de obligado cumplimiento.

Contacto

¡Gracias por su mensaje!

Visual contact Visual contact

Su mensaje se ha recibido con éxito en el buzón del SAT de TROX.
En seguida nos pondremos en contacto con usted.
En caso de que disponga de cuestiones adicionales, puede contactar con nosotros en: Tel.: +34 976 50 02 50 | Fax: +34 976 50 09 04

Contacto

Estamos aquí para ayudarle

Visual contact Visual contact

Por favor indique el asunto de su consulta y sus datos de contacto.
Tel.: +34 976 50 02 50 | Fax: +34 976 50 09 04

Adjunto (máx. 10MB)

Los campos marcados con un asterísco (*) son de obligado cumplimiento.

Contacto

¡Gracias por su mensaje!

Visual contact Visual contact

Su mensaje se ha recibido con éxito en el buzón del SAT de TROX.
En seguida nos pondremos en contacto con usted.
En caso de que disponga de cuestiones adicionales, puede contactar con nosotros en: Tel.: +34 976 50 02 50 | Fax: +34 976 50 09 04